When I actually went to the source for the 240hz claim, I didn’t reach the same conclusion as the testers?
Maybe they just let their rigol scope spit out 240hz, but 480hz worst case and I would actually say 960hz. I think what’s happening with the tandem oled is they both pwm at 480hz and 180 degrees out of phase giving effective 960hz when both are in use. Which appears to be most of the usable brightness.
Edit: I’m so confused.
“The PWM behavior is interesting, because we can see DC-dimming for all brightness levels. Usually, OLED panels use DC-Dimming only at higher brightness levels. The frequency is very low at 240 Hz, however, and this might be an issue for sensitive users, despite the DC-dimming. ” https://www.notebookcheck.net/Amazing-OLED-panel-Apple-MacBo...
Their method is a photo detector driving the oscilloscope, right?
How can they assume the rise/fall slope in those plots is characterizing the driving electrical signal? Wouldn't a PWM driver be able to have much faster transitions and look more square than that at these time scales?
It makes me wonder if this is the response of the organic phosphors and the difference in apparent "depth" of the dip is really just a difference of duration, since the dips are very V-shaped, rather than bottoming out.
It is slightly odd that it has this paired rhythm, but I don't think you can assume it is "DC-dimming" rather than just PWM quanta that are being anti-alias filtered by the phosphors and measurement methodology.
240 Hz looks correct to me. Of course it also has 480 Hz and other even higher components but the lowest significant component is 240 Hz. You can't disregard that half of the dips are much deeper. That will create a lower frequency flickering.
You’re right - looking at the scope pictures, the horizontal period of the grid is 2ms, and the period of the wave is just over that.
A 240Hz wave would have a period of 4.17ms. 480Hz is 2.08ms. Much closer to the oscilloscope waveforms. And even then the waveforms are periodic, with smaller troughs at every second dip.
I wish I could see their test setup. It would be ironic if the panel was fully DC dimmed and the troughs were from another light source or something…
I’m not sure why the scope is saying 240 though. It makes me doubt my understanding :-/.
[Edit: Ah - got it! It’s measuring the frequency of the very lowest points - the ‘every second dip’]